Q-Logic SN0135524-00 Manual de usuario Pagina 284

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 320
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 283
Sun StorEdge Network 2 Gb FC Series Switches
Timeout Values
P
AGE 272 QLOGIC SWITCH INTEROPERABILITY GUIDE
VERSION 1.0, MARCH 2003
Timeout Values
As per FC-SW-2 Fibre Channel standards, set all switches to the following timeout values (TOV)
in order to successfully establish an E-port connection:
R_A_TOV = 10 seconds
E_D_TOV = 2 seconds
This section provides the steps to change these values.
Sun StorEdge SANbox Manager GUI
ATTENTION!!
The following steps take the switch offline; therefore, do not perform them on a
switch being managed in-band.
1. Start the SANbox Manager application. The SANbox ManagerFaceplate dialog box
displays.
2. From the SANbox ManagerFaceplate dialog box Switch menu, select Switch Properties.
For the Sun StorEdge Network 2 Gb FC Switch-8 and Sun StorEdge Network 2 Gb FC
Switch-16, the following displays:
Vista de pagina 283
1 2 ... 279 280 281 282 283 284 285 286 287 288 289 ... 319 320

Comentarios a estos manuales

Sin comentarios