Q-Logic SN0135524-00 Manual de usuario Pagina 104

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 320
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 103
Cisco SN 5428 Storage Router
QLogic Specific Configuration
P
AGE 92 QLOGIC SWITCH INTEROPERABILITY GUIDE
VERSION 1.0, MARCH 2003
Cisco CLI
NOTE: Use the following CLI commands when the Cisco SN 5428 Management Interface is not
available.
ATTENTION!!
This procedure requires a reboot of the switch.
CISCO SN 5428 Storage Router
Password: *****
[Cisco_5428]$ ena
Enter admin password: *****
[Entering Administrator mode]
[Cisco_5428]# interface fc domainid zoning merge sw2
*[Cisco_5428]# save all bootconfig
QLogic Specific Configuration
Not applicable.
Successful Integration Checklist
Perform the following steps after the E-port connection has been established and the fabric has
had time to update. If everything verifies, the Cisco and QLogic fabrics have successfully merged.
Compare and verify that all Zoning information has been propagated on all switches.
Verify that the correct Zone Set is activated.
Compare and verify that all devices are in the Name Server of each switch.
Verify that all initiators continue to detect and have access to all targets that existed prior to the
fabric merger.
After everything is verified, your fabric has merged successfully and no additional steps need to
be taken. If any of the above tasks did not complete successfully, please contact QLogic support.
Vista de pagina 103
1 2 ... 99 100 101 102 103 104 105 106 107 108 109 ... 319 320

Comentarios a estos manuales

Sin comentarios