Q-Logic SN0135524-00 Manual de usuario Pagina 250

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 320
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 249
McDATA Intrepid 6000 Series Directors
Timeout Values
P
AGE 238 QLOGIC SWITCH INTEROPERABILITY GUIDE
VERSION 1.0, MARCH 2003
For the QLogic SANbox2-64, the following displays:
4. From the Switch PropertiesSANbox Manager dialog box Administrative State list, select
offline. Click OK.
5. Re-enter the Switch PropertiesSANbox Manager dialog box (see step 2). Do the
following:
a. In the R_A_TOV box, change the setting to 10000.
b. In the E_D_TOV box, change the setting to 2000.
c. Click OK.
6. Re-enter the Switch PropertiesSANbox Manager dialog box (see step 2). In the
Administrative State list, select Online. Click OK.
Vista de pagina 249
1 2 ... 245 246 247 248 249 250 251 252 253 254 255 ... 319 320

Comentarios a estos manuales

Sin comentarios