Vista de pagina 114
GigWorks MKII-16 Switch Model MKII-BASE16
Installer's/User's Manual 59003-01 Rev. A
Removal/Replacement Procedures 5-1
Section 5 Removal/Replacement
Procedures
Introduction
The only Field Replaceable Units (FRUs) in the Switch are Input Fuses, GBICs,
and the Power Supply(s).
Input Fuse
Removal
1. Unplug the AC Power Cable from the back of the Switch chassis.
2. Insert a thin-blade screwdriver into the slot behind the tab and use it to pull
the Fuse Holder out the front of the AC Power Plug Assembly.
3. Pull the Fuse(s) from the Fuse Holder.
Fuse Holder
Tab
Slot
behind
Tab
AC Power Plug Assembly